How to install Polycool Roof Inserts

Polycool Solar Control Inserts can be easily installed into your existing conservatory roof on a DIY basis if all roof channels are accessible from the gutter edge. N.B if all channels are fully accessible you will not need to lift or remove any roof panels during installation. Should you find that access to the conservatory is restricted or if you have a Valley or box gutter where panels do need to be lifted or removed, our experienced conservatory technicians can install the product for you. For more information on our fitting service call us on 01789 766880.

Easy step-by-step guide to installing Polycool Solar Control Inserts.

Standard Polycarbonate Roof Instructions

Polycool Installation Image Step 1 Polycool Installation Image Step 2 Polycool Installation Image Step 3
Polycool Installation Image Step 4 Polycool Installation Image Step 5 Polycool Installation Image Step 6
  1. Remove panel end capping
  2. Remove any sealing tape
  3. Punch a hole through the Solar inserts (using the hole punch provided)
  4. Insert film with the assistance of the Unique Polycool installation tool
  5. Cut the insert to length
  6. Replace breather tape and panel end caps

For Everlite, Ultralite 500 and other widespan conservatory roofs you will not need to remove or replace any breather tape, these roofs will have channel end plugs or a fascia board covering the end of the roof panels.

Full fitting instructions are provided with every order of Polycool,

Polycool Nationwide Installation Service

If time is at a premium or you would like us to fit on your behalf, call us on 01789 766880 for a competitive fitting quotation.

Our fully trainined Polycool installation technicians are highly skilled, friendly, reliable and have years of experience attending to all areas of conservatory roofs.

We do not use 'part time installers' or sub contractors who may not have the necessary skills or experience.

N.B - All Polycool fitting work is guaranteed for 12 months.

Polycool Technical Specifications

Film tested under ASHRAE & CEN10 conditions using ASHRAE, ASTM, IWFA and AIMCAL calculations and test procedures.

  Silver Film Gold Film
Total Solar Energy Rejected (typically) 85% 85%
Glare Reduction (typically) 85% 87%
UV Blocked (300-380 nanometers) 98% 99%
Increase in polycarbonate U Value (typically) 10% 10%
Increase in thermal resistance to heat loss 10%-15% 10%-15%
Film Thickness - unembossed (typically) - embossed (typically) 95 microns
175 - 200 microns
75 microns
140-150 microns

Performance results of solar film are subject to variations within industry standards and glazing configurations and will vary on the style of polycarbonate. They are nominal and only intended for estimating purposes.

Solar Film, Conservatory Roof, Solar Inserts, Conservatory Roof Inserts, Polycarbonate